Data coverage & sources
The stored record for FS-Curtis RSD200: specifications, configurations, documents, sources, and gaps.
One model, connected records
FS-Curtis → FS-Curtis RS Series 15-300HP → RSD200
Manufacturer model: RSD200 · OEM article / order number: Not collected · Equipment type: compressor
Technology: Reciprocating
Compare coverage across this familySpecifications and evidence
11 stored observations · 11 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Free air delivery · Sourced · 4 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 920 CFM | 1563.089 m3/h | Frequency not stated · model FAD 100 psi free air delivery | Source · OEM_SOURCECapacity FAD 100 psi: 920Retrieved 2026-10-05 |
| 860 CFM | 1461.149 m3/h | Frequency not stated · model FAD 125 psi free air delivery | Source · OEM_SOURCECapacity FAD 125 psi: 860Retrieved 2026-10-05 |
| 770 CFM | 1308.238 m3/h | Frequency not stated · model FAD 150 psi free air delivery | Source · OEM_SOURCECapacity FAD 150 psi: 770Retrieved 2026-10-05 |
| 680 CFM | 1155.327 m3/h | Frequency not stated · model FAD 175 psi free air delivery | Source · OEM_SOURCECapacity FAD 175 psi: 680Retrieved 2026-10-05 |
Max. pressure · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Motor power · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 160 / 200 / 200 kW / HP | — | Frequency not stated · model as printed: "Power kW / HP" unspecified | Source · OEM_SOURCERSD200 | 160 / 200 | 920 | 860 | 770 | 680 | Base Mount | 87 | 90 x 80 x 75 | 5250Retrieved 2026-10-20 |
Speed · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Noise level · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 87 dB(A) | 87 dB(A) | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCESound Level: 87Retrieved 2026-10-05 |
Weight · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 5250 lbs. | 2381.358 kg | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCEWeight: 5250Retrieved 2026-10-05 |
Dimensions · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Inlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Outlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Reference working pressure · Sourced · 4 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 175 psi | 12065.83 mbar | Frequency not stated · model the pressure "Capacity FAD 175 psi" is stated at (FAD 175 psi) free air delivery | Source · OEM_SOURCECapacity FAD 175 psi: 680Retrieved 2026-10-20 |
| 125 psi | 8618.45 mbar | Frequency not stated · model the pressure "Capacity FAD 125 psi" is stated at (FAD 125 psi) free air delivery | Source · OEM_SOURCECapacity FAD 125 psi: 860Retrieved 2026-10-20 |
| 150 psi | 10342.14 mbar | Frequency not stated · model the pressure "Capacity FAD 150 psi" is stated at (FAD 150 psi) free air delivery | Source · OEM_SOURCECapacity FAD 150 psi: 770Retrieved 2026-10-20 |
| 100 psi | 6894.76 mbar | Frequency not stated · model the pressure "Capacity FAD 100 psi" is stated at (FAD 100 psi) free air delivery | Source · OEM_SOURCECapacity FAD 100 psi: 920Retrieved 2026-10-20 |
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 0 | 0 | Not collected |
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 0 | 0 | Not collected |
| Parts documentation | 3 | 0 |
|
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 1 | 0 |
|
| Other / unclassified | 0 | 0 | Not collected |