Data coverage & sources
The stored record for Leybold LV 80: specifications, configurations, documents, sources, and gaps.
One model, connected records
Leybold → LEYVAC Dry screw vacuum pumps → LV 80
Manufacturer model: LV 80 · OEM article / order number: Not collected · Equipment type: vacuum pump
Technology: Dry Screw
Related applications: Degassing, Drying, Process Vacuum
Related industries: Chemical, Oil + Gas, Pharmaceutical, Semiconductor
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
22 stored observations · 13 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Pumping speed · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 80 m3/h | 80 m3/h | Frequency not stated · model 50 Hz; without gas ballast at 50/60 Hz unspecified | Source · OEM_SOURCENominal pumping speed without gas ballast at 50/60 Hz: 80Retrieved 2026-10-01 |
| 96 m3/h | 96 m3/h | Frequency not stated · model 60 Hz; without gas ballast at 50/60 Hz unspecified | Source · OEM_SOURCENominal pumping speed without gas ballast at 50/60 Hz: 96Retrieved 2026-10-01 |
Ultimate pressure · Needs review · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 1 x 10 -2 mbar | 0.01 mbar | Frequency not stated · range with seal and rotor purge unspecified | Source · OEM_SOURCE not a model rating Ultimate pressure with seal and rotor purge: 1 x 10 -2Retrieved 2026-10-01 |
Motor power · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 4.1 kW | 4.1 kW | Frequency not stated · model at 50/60 Hz unspecified | Source · OEM_SOURCENominal power at 50/60 Hz: 4.1Retrieved 2026-10-01 |
Speed · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Noise level · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| < 65 dB(A) | 65 dB(A) | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCENoise level: < 65Retrieved 2026-10-01 |
Weight · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 280 kg | 280 kg | Frequency not stated · model approx. unspecified | Source · OEM_SOURCEWeight, approx.: 280Retrieved 2026-10-01 |
Dimensions · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 814 x 375 x 550 mm | — | Frequency not stated · model (W x H x D) unspecified | Source · OEM_SOURCEDimensions (W x H x D): 814 x 375 x 550Retrieved 2026-10-01 |
Inlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Outlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Ambient temperature · Needs review · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 5-45 °C | 5 °C | Frequency not stated · range temperature unspecified | Source · OEM_SOURCE not a model rating Permissible ambient temperature: 5-45Retrieved 2026-10-01 |
Cooling · Needs review · 1 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| water/glycol Cooling | — | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCECooling: water/glycolRetrieved 2026-10-01 |
Exhaust Side Connection · Needs review · 1 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 40 ISO-KF ISO-KF DN | — | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCEExhaust side connection: 40 ISO-KFRetrieved 2026-10-01 |
Intake Connection · Needs review · 1 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 63 ISO-K ISO-K DN | — | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCEIntake connection: 63 ISO-KRetrieved 2026-10-01 |
Mains Voltage 10 · Needs review · 1 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 200 - 460 V | 200 V | Frequency not stated · range Conditions not stated unspecified | Source · OEM_SOURCE not a model rating Mains voltage (+/- 10%): 200 - 460Retrieved 2026-10-01 |
Nominal Current At 50 60 Hz · Needs review · 1 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 6 A | 6 A | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCENominal current at 50/60 Hz: 6Retrieved 2026-10-01 |
Power consumption · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 2.9 kW | 2.9 kW | Frequency not stated · model 50 Hz; at ultimate pressure at 50/60 Hz unspecified | Source · OEM_SOURCEPower consumption at ultimate pressure at 50/60 Hz: 2.9Retrieved 2026-10-01 |
| 3.2 kW | 3.2 kW | Frequency not stated · model 60 Hz; at ultimate pressure at 50/60 Hz unspecified | Source · OEM_SOURCEPower consumption at ultimate pressure at 50/60 Hz: 3.2Retrieved 2026-10-01 |
Protection Class En 60529 · Needs review · 1 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 54 IP | — | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCEProtection class EN 60529: 54Retrieved 2026-10-01 |
Service liquid flow · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 5-35 °C | 5 °C | Frequency not stated · range temperature unspecified | Source · OEM_SOURCE not a model rating Cooling water temperature: 5-35Retrieved 2026-10-01 |
| 3 l/min | 0.18 m3/h | Frequency not stated · model throughput unspecified | Source · OEM_SOURCECooling water throughput: 3Retrieved 2026-10-01 |
Water vapour tolerance · Sourced · 4 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 20 mbar | 20 mbar | Frequency not stated · model 50 Hz; with gas ballast 50/60 Hz unspecified | Source · OEM_SOURCEWater vapor tolerance with gas ballast 50/60 Hz: 20Retrieved 2026-10-01 |
| 30 mbar | 30 mbar | Frequency not stated · model 60 Hz; with gas ballast 50/60 Hz unspecified | Source · OEM_SOURCEWater vapor tolerance with gas ballast 50/60 Hz: 30Retrieved 2026-10-01 |
| 1.24 kg/h | 1.24 kg/h | Frequency not stated · model 50 Hz; with gas ballast 50/60 Hz unspecified | Source · OEM_SOURCEWater vapor capacity with gas ballast 50/60 Hz: 1.24Retrieved 2026-10-01 |
| 2.3 kg/h | 2.3 kg/h | Frequency not stated · model 60 Hz; with gas ballast 50/60 Hz unspecified | Source · OEM_SOURCEWater vapor capacity with gas ballast 50/60 Hz: 2.3Retrieved 2026-10-01 |
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 0 | 0 | Not collected |
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 0 | 0 | Not collected |
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 0 | 0 | Not collected |
| Other / unclassified | 0 | 0 | Not collected |