Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Leybold · TRIVAC L Double-stage rotary vane vacuum pumps

TRIVAC D 5 L

Leybold TRIVAC D 5 L

*Photo shows another model from the Leybold Oil-Lubricated Rotary Vane range, not this exact model. Image: Leybold

Weight
24 kg

Headline ratings converted to common units for comparison; the table below shows each figure exactly as published.

Technical data

Source: Leybold product page · retrieved 2026-10-01
As published50 Hz; 50Hzwithout gas ballastwith gas ballast in position 1 and 2Value50 Hz; w/o GB 50Hz50 Hzw/o oilflangeas printed: "1 Phase Motor 50Hz"as printed: "3 Phase Motor 50Hz"
Nominal pumping speed 50Hz
Pumping speed
5,8 m3/h
oem source
Source · 2026-10-01
Pumping speed 50Hz
Pumping speed
5,1 m3/h
oem source
Source · 2026-10-01
Ultimate total pressure without gas ballast
Ultimate pressure
2×10 -3 mbarR
Needs review · excluded from comparison
Source · 2026-10-01
Ultimate total pressure with gas ballast in position 1 and 2
Ultimate pressure
3×10 -2/1×10 -1 /0.1 mbarR
Needs review · excluded from comparison
Source · 2026-10-01
Water vapor tolerance with gas ballast in position 1 and 2
Water vapour tolerance
11/32 /32 mbar
oem source
Source · 2026-10-01
Water vapor pumping rate with gas ballast in position 1 and 2
0.04/0.12 /0.12 kg/h
oem source
Source · 2026-10-01
Noise level w/o GB 50Hz
Noise level
50 dB(A)
oem source
Source · 2026-10-01
Maximum permitted inlet pressure
0,05 bar. G
oem source
Source · 2026-10-01
Maximum permitted outlet pressure
0,2 bar. G
oem source
Source · 2026-10-01
1 Phase Motor 50Hz
0,37 KW
oem source
Source · 2026-10-01
3 Phase Motor 50Hz
0,37 KW
oem source
Source · 2026-10-01
Weight w/o oil
Weight
24 kg
oem source
Source · 2026-10-01
Length x Width x Height
479 x 174 x 272 mm
oem source
Source · 2026-10-01
Oil volume
Oil capacity
0.45~0.7 ~0.7 L
oem source
Source · 2026-10-01
Feet dimension (Length x Width)
280 x97 mm
oem source
Source · 2026-10-01
Inlet flange
Inlet connection
25 KF
oem source
Source · 2026-10-01
Outlet flange
Outlet connection
25 KF
oem source
Source · 2026-10-01
Air inlet and air outlet position
Air inlet on coupling housing and air outlet on oil casing
oem source
Source · 2026-10-01
Motor power
0,37 KW
oem source
Source · 2026-10-20
0,37 KW
oem source
Source · 2026-10-20

Original extracted values are shown with their source and review status. Multiple values under the same condition remain separate for review.

R a min–max range as published, not a single rating

Same family: TRIVAC D 12 L, TRIVAC D 40 L, TRIVAC D 63 L, TRIVAC D 90 L

Reviewed operating performance · 60 Hz

Loading reviewed performance…

Documents

    Documents open on the manufacturer’s site.

    Service parts

    No parts published for this model.

    Compare with another model

    Not on file yet

    • MissingLeybold's parts drawing (exploded view) for the TRIVAC D 5 L
    • MissingA parts list for the TRIVAC D 5 L
    • MissingManuals or parts lists from Leybold

    We don’t have these from Leybold yet. A specialist can still help you find the right part for the TRIVAC D 5 L.