The stored record for Leybold VARODRY VD 200: specifications, configurations, documents, sources, and gaps.
One model, connected records
Leybold → VARODRY Dry screw vacuum pumps - oil-free design → VARODRY VD 200
Manufacturer model: VARODRY VD 200 · OEM article / order number: Not collected · Equipment type: vacuum pump
Technology: Dry Screw
Related applications: Degassing, Drying, Process Vacuum
Related industries: Chemical, Oil + Gas, Pharmaceutical, Semiconductor
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
14 stored observations · 10 pass the source policy at 50 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Pumping speed · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 200 m3/h | 200 m3/h | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCEMax. pumping speed: 200Retrieved 2026-10-01 |
Ultimate pressure · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| < 0.01 mbar | 0.01 mbar | Frequency not stated · model without gas ballast unspecified | Source · OEM_SOURCEUltimate pressure without gas ballast: < 0.01Retrieved 2026-10-01 |
Motor power · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 4.0 kW | 4 kW | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCERated motor power: 4.0Retrieved 2026-10-01 |
Speed · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Noise level · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 65 dB(A) | 65 dB(A) | Frequency not stated · model 50 Hz; (with built-in silencer) at ultimate pressure (50 / 60 Hz)** unspecified | Source · OEM_SOURCENoise level (with built-in silencer) at ultimate pressure (50 / 60 Hz)**: 65Retrieved 2026-10-01 |
| 69 dB(A) | 69 dB(A) | Frequency not stated · model 60 Hz; (with built-in silencer) at ultimate pressure (50 / 60 Hz)** unspecified | Source · OEM_SOURCENoise level (with built-in silencer) at ultimate pressure (50 / 60 Hz)**: 69Retrieved 2026-10-01 |
Weight · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 130 kg | 130 kg | Frequency not stated · model approx. unspecified | Source · OEM_SOURCEWeight, approx.: 130Retrieved 2026-10-01 |
Dimensions · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Inlet connection · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| G 2“ (In) / G 1 1/2“ (Out) | — | Frequency not stated · model / outlet connection unspecified | Source · OEM_SOURCEInlet / outlet connection: G 2“ (In) / G 1 1/2“ (Out)Retrieved 2026-10-01 |
Outlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Ambient temperature · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 0 to +40 to +40 °C | — | Frequency not stated · model temperature unspecified | Source · OEM_SOURCEPermissible ambient temperature: 0 to +40Retrieved 2026-10-01 |
Max Permissible Inlet Pressure · Needs review · 1 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 1050 mbar | 1050 mbar | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCEMax. permissible inlet pressure: 1050Retrieved 2026-10-01 |
Max Permissible Outlet Pressure Rel To Ambient · Needs review · 1 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 200 mbar | 200 mbar | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCEMax. permissible outlet pressure (rel. to ambient): 200Retrieved 2026-10-01 |
Protection Class · Needs review · 1 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| IP55 | — | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCEProtection class: IP55Retrieved 2026-10-01 |
Water vapour tolerance · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 60 mbar | 60 mbar | Frequency not stated · model with gas ballast unspecified | Source · OEM_SOURCEWater vapor tolerance with gas ballast: 60Retrieved 2026-10-01 |
| 6.9 kg/h | 6.9 kg/h | Frequency not stated · model with gas ballast unspecified | Source · OEM_SOURCEWater vapor capacity with gas ballast: 6.9Retrieved 2026-10-01 |
With Gas Ballast · Needs review · 1 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| < 0.1 mbar | 0.1 mbar | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCEwith gas ballast: < 0.1Retrieved 2026-10-01 |
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 0 | 0 | Not collected |
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 0 | 0 | Not collected |
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 3 | 0 |
|