Data coverage & sources
The stored record for Mark Compressors MSA 11: specifications, configurations, documents, sources, and gaps.
One model, connected records
Mark Compressors → Mark MSA technical data → MSA 11
Manufacturer model: MSA 11 · OEM article / order number: Not collected · Equipment type: compressor
Technology: Rotary Screw
Related applications: Plant Air, Pressure Conveying, Spray + Finishing
Related industries: Automotive, Chemical, General Manufacturing, Metalworking, Mining, Oil + Gas, Packaging, Plastics, Power Generation, Printing, Pulp + Paper, Water + Wastewater, Woodworking + CNC
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
11 stored observations · 11 pass the source policy at 50 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Free air delivery · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 28.3 l/s | 101.88 m3/h | 50 Hz · model 8 bar version, 50 Hz free air delivery | Source · OEM_SOURCEFree air delivery: 28.3Retrieved 2026-10-03 |
| 25.9 l/s | 93.24 m3/h | 50 Hz · model 10 bar version, 50 Hz free air delivery | Source · OEM_SOURCEFree air delivery: 25.9Retrieved 2026-10-03 |
| 19.1 l/s | 68.76 m3/h | 50 Hz · model 13 bar version, 50 Hz free air delivery | Source · OEM_SOURCEFree air delivery: 19.1Retrieved 2026-10-03 |
Max. pressure · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Motor power · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 11 kW | 11 kW | 50 Hz · model 50 Hz unspecified | Source · OEM_SOURCEMotor power: 11Retrieved 2026-10-03 |
Speed · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Noise level · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Weight · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 450 kg | 450 kg | Frequency not stated · model as printed: "FF TM 500L" unspecified | Source · OEM_SOURCE11 15 67 255 385 450Retrieved 2026-10-20 |
| 255 kg | 255 kg | Frequency not stated · model as printed: "PACK" unspecified | Source · OEM_SOURCE11 15 67 255 385 450Retrieved 2026-10-20 |
| 385 kg | 385 kg | Frequency not stated · model as printed: "FF TM 270L" unspecified | Source · OEM_SOURCE11 15 67 255 385 450Retrieved 2026-10-20 |
Dimensions · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Inlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Outlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Max. working pressure · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 13 Bar | 13000 mbar | 50 Hz · model 50 Hz unspecified | Source · OEM_SOURCEMax. working pressure: 13Retrieved 2026-10-03 |
Reference working pressure · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 7.5 Bar | 7500 mbar | 50 Hz · model 8 bar version, 50 Hz unspecified | Source · OEM_SOURCEReference working pressure: 7.5Retrieved 2026-10-03 |
| 9.5 Bar | 9500 mbar | 50 Hz · model 10 bar version, 50 Hz unspecified | Source · OEM_SOURCEReference working pressure: 9.5Retrieved 2026-10-03 |
| 12.5 Bar | 12500 mbar | 50 Hz · model 13 bar version, 50 Hz unspecified | Source · OEM_SOURCEReference working pressure: 12.5Retrieved 2026-10-03 |
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 1 | 0 |
|
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 0 | 0 | Not collected |
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 1 | 0 |
|