Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for Pneumatic Products 59NGPLS: specifications, configurations, documents, sources, and gaps.

One model, connected records

Pneumatic Products → NGPLS – Light Duty Nitrogen Generator → 59NGPLS

Manufacturer model: 59NGPLS · OEM article / order number: Not collected · Equipment type: gas generator

Technology: Nitrogen Generators / Air Treatment

Related applications: Plant Air
Related industries: Not mapped

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

24 stored observations · 24 pass the source policy at 50 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Gas output · Sourced · 22 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
49.6 scfm84.2709 m3/hFrequency not stated · model
at 95% purity, 70 °F ambient, 110 psig inlet
standard
Source · OEM_SOURCE
Flow: 49.6
Retrieved 2026-10-05
45.2 scfm76.7953 m3/hFrequency not stated · model
at 96% purity, 70 °F ambient, 110 psig inlet
standard
Source · OEM_SOURCE
Flow: 45.2
Retrieved 2026-10-05
41.6 scfm70.6788 m3/hFrequency not stated · model
at 97% purity, 70 °F ambient, 110 psig inlet
standard
Source · OEM_SOURCE
Flow: 41.6
Retrieved 2026-10-05
35.0 scfm59.4653 m3/hFrequency not stated · model
at 98% purity, 70 °F ambient, 110 psig inlet
standard
Source · OEM_SOURCE
Flow: 35.0
Retrieved 2026-10-05
28.2 scfm47.9121 m3/hFrequency not stated · model
at 99% purity, 70 °F ambient, 110 psig inlet
standard
Source · OEM_SOURCE
Flow: 28.2
Retrieved 2026-10-05
24.9 scfm42.3053 m3/hFrequency not stated · model
at 99.5% purity, 70 °F ambient, 110 psig inlet
standard
Source · OEM_SOURCE
Flow: 24.9
Retrieved 2026-10-05
18.8 scfm31.9414 m3/hFrequency not stated · model
at 99.9% purity, 70 °F ambient, 110 psig inlet
standard
Source · OEM_SOURCE
Flow: 18.8
Retrieved 2026-10-05
16.6 scfm28.2036 m3/hFrequency not stated · model
at 99.95% purity, 70 °F ambient, 110 psig inlet
standard
Source · OEM_SOURCE
Flow: 16.6
Retrieved 2026-10-05
12.5 scfm21.2376 m3/hFrequency not stated · model
at 99.99% purity, 70 °F ambient, 110 psig inlet
standard
Source · OEM_SOURCE
Flow: 12.5
Retrieved 2026-10-05
10.8 scfm18.3493 m3/hFrequency not stated · model
at 99.995% purity, 70 °F ambient, 110 psig inlet
standard
Source · OEM_SOURCE
Flow: 10.8
Retrieved 2026-10-05
8.2 scfm13.9319 m3/hFrequency not stated · model
at 99.999% purity, 70 °F ambient, 110 psig inlet
standard
Source · OEM_SOURCE
Flow: 8.2
Retrieved 2026-10-05
46.7 scfm79.3438 m3/hFrequency not stated · model
at 95% purity, 95 °F ambient, 110 psig inlet
standard
Source · OEM_SOURCE
Flow: 46.7
Retrieved 2026-10-05
43.2 scfm73.3972 m3/hFrequency not stated · model
at 96% purity, 95 °F ambient, 110 psig inlet
standard
Source · OEM_SOURCE
Flow: 43.2
Retrieved 2026-10-05
38.6 scfm65.5818 m3/hFrequency not stated · model
at 97% purity, 95 °F ambient, 110 psig inlet
standard
Source · OEM_SOURCE
Flow: 38.6
Retrieved 2026-10-05
33.1 scfm56.2372 m3/hFrequency not stated · model
at 98% purity, 95 °F ambient, 110 psig inlet
standard
Source · OEM_SOURCE
Flow: 33.1
Retrieved 2026-10-05
26.6 scfm45.1937 m3/hFrequency not stated · model
at 99% purity, 95 °F ambient, 110 psig inlet
standard
Source · OEM_SOURCE
Flow: 26.6
Retrieved 2026-10-05
23.1 scfm39.2471 m3/hFrequency not stated · model
at 99.5% purity, 95 °F ambient, 110 psig inlet
standard
Source · OEM_SOURCE
Flow: 23.1
Retrieved 2026-10-05
17.1 scfm29.0531 m3/hFrequency not stated · model
at 99.9% purity, 95 °F ambient, 110 psig inlet
standard
Source · OEM_SOURCE
Flow: 17.1
Retrieved 2026-10-05
15.0 scfm25.4851 m3/hFrequency not stated · model
at 99.95% purity, 95 °F ambient, 110 psig inlet
standard
Source · OEM_SOURCE
Flow: 15.0
Retrieved 2026-10-05
11.1 scfm18.859 m3/hFrequency not stated · model
at 99.99% purity, 95 °F ambient, 110 psig inlet
standard
Source · OEM_SOURCE
Flow: 11.1
Retrieved 2026-10-05
9.8 scfm16.6503 m3/hFrequency not stated · model
at 99.995% purity, 95 °F ambient, 110 psig inlet
standard
Source · OEM_SOURCE
Flow: 9.8
Retrieved 2026-10-05
7.2 scfm12.2329 m3/hFrequency not stated · model
at 99.999% purity, 95 °F ambient, 110 psig inlet
standard
Source · OEM_SOURCE
Flow: 7.2
Retrieved 2026-10-05
Max. pressure · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Power consumption · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Dimensions · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Reference working pressure · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
110 psig110 psigFrequency not stated · model
the pressure "Flow" is stated at (at 95% purity, 70 °F ambient, 110 psig inlet)
unspecified
Source · OEM_SOURCE
Flow: 49.6
Retrieved 2026-10-20
Weight · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
1292 lb.586.0409 kgFrequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Weight: 1292
Retrieved 2026-10-05

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications00Not collected
Performance curves / test data00Not collected
Operation / service manuals00Not collected
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature10