Data coverage & sources
The stored record for Pneumofore UV30: specifications, configurations, documents, sources, and gaps.
One model, connected records
Pneumofore → Pneumofore UV Series → UV30
Manufacturer model: UV30 · OEM article / order number: Not collected · Equipment type: vacuum pump
Technology: Oil-Lubricated Rotary Vane
Related applications: Central Vacuum, Degassing, Drying, Leak Testing, Medical Suction, Packaging, Vacuum Forming
Related industries: Automotive, Food + Beverage, Medical, Metalworking, Packaging, Plastics
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
18 stored observations · 11 pass the source policy at 50 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Pumping speed · Sourced · 6 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 1.759 m³/h | 1759 m3/h | 50 Hz · model 100 mbar(a), 50 Hz unspecified | Source · OEM_SOURCECapacity: 1.759Retrieved 2026-10-03 |
| 2.076 m³/h | 2076 m3/h | 60 Hz · model 100 mbar(a), 60 Hz unspecified | Source · OEM_SOURCE different frequency Capacity: 2.076Retrieved 2026-10-03 |
| 1.801 m³/h | 1801 m3/h | 50 Hz · model 200 mbar(a), 50 Hz unspecified | Source · OEM_SOURCECapacity: 1.801Retrieved 2026-10-03 |
| 2.125 m³/h | 2125 m3/h | 60 Hz · model 200 mbar(a), 60 Hz unspecified | Source · OEM_SOURCE different frequency Capacity: 2.125Retrieved 2026-10-03 |
| 1.806 m³/h | 1806 m3/h | 50 Hz · model 300 mbar(a), 50 Hz unspecified | Source · OEM_SOURCECapacity: 1.806Retrieved 2026-10-03 |
| 2.132 m³/h | 2132 m3/h | 60 Hz · model 300 mbar(a), 60 Hz unspecified | Source · OEM_SOURCE different frequency Capacity: 2.132Retrieved 2026-10-03 |
Ultimate pressure · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 0,5 mbar(a) | 0.5 mbar | Frequency not stated · series as printed: "residual pressure"; stated for the whole series unspecified | Source · OEM_SOURCEModels from UV4 to UV100 with a capacity range of 250 to 7.160 m 3/h and up to 0,5 mbar(a) residual pressure.Retrieved 2026-10-20 |
Motor power · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 45 kW | 45 kW | 50 Hz · model 50 Hz unspecified | Source · OEM_SOURCENominal power: 45Retrieved 2026-10-03 |
Speed · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Noise level · Sourced · 2 observations / 1 sources
Weight · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 2.095 kg | 2095 kg | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCEWeight: 2.095Retrieved 2026-10-03 |
Dimensions · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Inlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Outlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Max. vacuum · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 99,95 % | 99.95 % | Frequency not stated · series as printed: "maximum vacuum degree"; stated for the whole series; 0,5 mbar(a) unspecified | Source · OEM_SOURCE99,95% maximum vacuum degree [0,5 mbar(a) residual absolute pressure]Retrieved 2026-10-20 |
Power consumption · Sourced · 6 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 34 kW | 34 kW | 50 Hz · model 100 mbar(a), 50 Hz unspecified | Source · OEM_SOURCEAbsorbed power: 34Retrieved 2026-10-03 |
| 45 kW | 45 kW | 60 Hz · model 100 mbar(a), 60 Hz unspecified | Source · OEM_SOURCE different frequency Absorbed power: 45Retrieved 2026-10-03 |
| 37 kW | 37 kW | 50 Hz · model 200 mbar(a), 50 Hz unspecified | Source · OEM_SOURCEAbsorbed power: 37Retrieved 2026-10-03 |
| 48 kW | 48 kW | 60 Hz · model 200 mbar(a), 60 Hz unspecified | Source · OEM_SOURCE different frequency Absorbed power: 48Retrieved 2026-10-03 |
| 40 kW | 40 kW | 50 Hz · model 300 mbar(a), 50 Hz unspecified | Source · OEM_SOURCEAbsorbed power: 40Retrieved 2026-10-03 |
| 50 kW | 50 kW | 60 Hz · model 300 mbar(a), 60 Hz unspecified | Source · OEM_SOURCE different frequency Absorbed power: 50Retrieved 2026-10-03 |
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 1 | 0 |
|
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 0 | 0 | Not collected |
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 2 | 0 |
|
| Other / unclassified | 0 | 0 | Not collected |