Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

FPZ · FPZ side channel blowers

e07 TD

FPZ e07 TD

*Photo shows the Side channel blowers series, not necessarily this exact model. Image: FPZ

Pumping speed
521 m³/h
Motor power
5.5 kW
Max. pressure
0.45 bar
Max. vacuum
400 mbar

Headline ratings converted to common units for comparison; the table below shows each figure exactly as published.

Technical data

Source: FPZ product page · retrieved 2026-10-05
As published50 Hz; compression50 Hz; compression; at max. flow50 Hz; compression; at +50 hPa (mbar)50 Hz; compression; at +100 hPa (mbar)50 Hz; compression; at +150 hPa (mbar)50 Hz; compression; at +200 hPa (mbar)50 Hz; compression; at +250 hPa (mbar)50 Hz; compression; at +300 hPa (mbar)50 Hz; compression; at +350 hPa (mbar)50 Hz; compression; at +400 hPa (mbar)50 Hz; compression; at +450 hPa (mbar)50 Hz; compression; at +500 hPa (mbar)50 Hz; compression; at +550 hPa (mbar)50 Hz; compression; at Δp max 550 mbar50 Hz; vacuum50 Hz; vacuum; at max. flow50 Hz; vacuum; at -50 hPa (mbar)50 Hz; vacuum; at -100 hPa (mbar)50 Hz; vacuum; at -150 hPa (mbar)50 Hz; vacuum; at -200 hPa (mbar)50 Hz; vacuum; at -250 hPa (mbar)50 Hz; vacuum; at -300 hPa (mbar)50 Hz; vacuum; at -350 hPa (mbar)50 Hz; vacuum; at -400 hPa (mbar)50 Hz; vacuum; at Δp max 400 mbar60 Hz; compression60 Hz; compression; at max. flow60 Hz; compression; at +50 hPa (mbar)60 Hz; compression; at +100 hPa (mbar)60 Hz; compression; at +150 hPa (mbar)60 Hz; compression; at +200 hPa (mbar)60 Hz; compression; at +250 hPa (mbar)60 Hz; compression; at +300 hPa (mbar)60 Hz; compression; at +350 hPa (mbar)60 Hz; compression; at +400 hPa (mbar)60 Hz; compression; at +450 hPa (mbar)60 Hz; compression; at Δp max 450 mbar60 Hz; vacuum60 Hz; vacuum; at max. flow60 Hz; vacuum; at -50 hPa (mbar)60 Hz; vacuum; at -100 hPa (mbar)60 Hz; vacuum; at -150 hPa (mbar)60 Hz; vacuum; at -200 hPa (mbar)60 Hz; vacuum; at -250 hPa (mbar)60 Hz; vacuum; at -300 hPa (mbar)60 Hz; vacuum; at -350 hPa (mbar)60 Hz; vacuum; at -400 hPa (mbar)60 Hz; vacuum; at Δp max 400 mbar
Max. flow
Pumping speed
432 m³/h
oem source
Source · 2026-10-05
432 m³/h
oem source
Source · 2026-10-05
521 m³/h
oem source
Source · 2026-10-05
521 m³/h
oem source
Source · 2026-10-05
Installed motor size
Motor power
5.50 kW
oem source
Source · 2026-10-05
9.20 kW
oem source
Source · 2026-10-05
5.50 kW
oem source
Source · 2026-10-05
7.50 kW
oem source
Source · 2026-10-05
5.50 kW
oem source
Source · 2026-10-05
9.20 kW
oem source
Source · 2026-10-05
5.50 kW
oem source
Source · 2026-10-05
9.20 kW
oem source
Source · 2026-10-05
Flow
Pumping speed
410 m³/h
oem source
Source · 2026-10-05
389 m³/h
oem source
Source · 2026-10-05
369 m³/h
oem source
Source · 2026-10-05
349 m³/h
oem source
Source · 2026-10-05
330 m³/h
oem source
Source · 2026-10-05
311 m³/h
oem source
Source · 2026-10-05
293 m³/h
oem source
Source · 2026-10-05
276 m³/h
oem source
Source · 2026-10-05
259 m³/h
oem source
Source · 2026-10-05
242 m³/h
oem source
Source · 2026-10-05
226 m³/h
oem source
Source · 2026-10-05
406 m³/h
oem source
Source · 2026-10-05
382 m³/h
oem source
Source · 2026-10-05
356 m³/h
oem source
Source · 2026-10-05
327 m³/h
oem source
Source · 2026-10-05
297 m³/h
oem source
Source · 2026-10-05
265 m³/h
oem source
Source · 2026-10-05
230 m³/h
oem source
Source · 2026-10-05
194 m³/h
oem source
Source · 2026-10-05
502 m³/h
oem source
Source · 2026-10-05
484 m³/h
oem source
Source · 2026-10-05
466 m³/h
oem source
Source · 2026-10-05
449 m³/h
oem source
Source · 2026-10-05
432 m³/h
oem source
Source · 2026-10-05
415 m³/h
oem source
Source · 2026-10-05
398 m³/h
oem source
Source · 2026-10-05
382 m³/h
oem source
Source · 2026-10-05
366 m³/h
oem source
Source · 2026-10-05
496 m³/h
oem source
Source · 2026-10-05
474 m³/h
oem source
Source · 2026-10-05
450 m³/h
oem source
Source · 2026-10-05
424 m³/h
oem source
Source · 2026-10-05
397 m³/h
oem source
Source · 2026-10-05
368 m³/h
oem source
Source · 2026-10-05
338 m³/h
oem source
Source · 2026-10-05
306 m³/h
oem source
Source · 2026-10-05
Δp max (compression)
Max. pressure
550 mbar
oem source
Source · 2026-10-05
450 mbar
oem source
Source · 2026-10-05
Δp max (vacuum)
Max. vacuum
400 mbar
oem source
Source · 2026-10-05
400 mbar
oem source
Source · 2026-10-05

Original extracted values are shown with their source and review status. Multiple values under the same condition remain separate for review.

Same family: e08 TD, e09 TD, e10 TD, e11 TD, e12 TD, K04 TD, K05 TD, K06 TD

Reviewed operating performance · 60 Hz

Loading reviewed performance…

Documents

Documents open on the manufacturer’s site.

Service parts

No parts published for this model.

Compare with another model

Not on file yet

  • MissingFPZ's parts drawing (exploded view) for the e07 TD
  • MissingA parts list for the e07 TD

We don’t have these from FPZ yet. A specialist can still help you find the right part for the e07 TD.