Data coverage & sources
The stored record for FPZ e07 TD: specifications, configurations, documents, sources, and gaps.
One model, connected records
FPZ → FPZ side channel blowers → e07 TD
Manufacturer model: e07 TD · OEM article / order number: Not collected · Equipment type: vacuum pump
Technology: Regenerative / Side Channel
Related applications: Material Handling, Pick + Place, Pneumatic Conveying, Vacuum Hold-Down
Related industries: Printing, Pulp + Paper, Woodworking + CNC
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
52 stored observations · 25 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Pumping speed · Sourced · 40 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 432 m³/h | 432 m3/h | 50 Hz · model 50 Hz; compression unspecified | Source · OEM_SOURCE different frequency Max. flow: 432Retrieved 2026-10-05 |
| 410 m³/h | 410 m3/h | 50 Hz · model 50 Hz; compression; at +50 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 410Retrieved 2026-10-05 |
| 389 m³/h | 389 m3/h | 50 Hz · model 50 Hz; compression; at +100 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 389Retrieved 2026-10-05 |
| 369 m³/h | 369 m3/h | 50 Hz · model 50 Hz; compression; at +150 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 369Retrieved 2026-10-05 |
| 349 m³/h | 349 m3/h | 50 Hz · model 50 Hz; compression; at +200 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 349Retrieved 2026-10-05 |
| 330 m³/h | 330 m3/h | 50 Hz · model 50 Hz; compression; at +250 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 330Retrieved 2026-10-05 |
| 311 m³/h | 311 m3/h | 50 Hz · model 50 Hz; compression; at +300 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 311Retrieved 2026-10-05 |
| 293 m³/h | 293 m3/h | 50 Hz · model 50 Hz; compression; at +350 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 293Retrieved 2026-10-05 |
| 276 m³/h | 276 m3/h | 50 Hz · model 50 Hz; compression; at +400 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 276Retrieved 2026-10-05 |
| 259 m³/h | 259 m3/h | 50 Hz · model 50 Hz; compression; at +450 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 259Retrieved 2026-10-05 |
| 242 m³/h | 242 m3/h | 50 Hz · model 50 Hz; compression; at +500 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 242Retrieved 2026-10-05 |
| 226 m³/h | 226 m3/h | 50 Hz · model 50 Hz; compression; at +550 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 226Retrieved 2026-10-05 |
| 432 m³/h | 432 m3/h | 50 Hz · model 50 Hz; vacuum unspecified | Source · OEM_SOURCE different frequency Max. flow: 432Retrieved 2026-10-05 |
| 406 m³/h | 406 m3/h | 50 Hz · model 50 Hz; vacuum; at -50 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 406Retrieved 2026-10-05 |
| 382 m³/h | 382 m3/h | 50 Hz · model 50 Hz; vacuum; at -100 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 382Retrieved 2026-10-05 |
| 356 m³/h | 356 m3/h | 50 Hz · model 50 Hz; vacuum; at -150 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 356Retrieved 2026-10-05 |
| 327 m³/h | 327 m3/h | 50 Hz · model 50 Hz; vacuum; at -200 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 327Retrieved 2026-10-05 |
| 297 m³/h | 297 m3/h | 50 Hz · model 50 Hz; vacuum; at -250 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 297Retrieved 2026-10-05 |
| 265 m³/h | 265 m3/h | 50 Hz · model 50 Hz; vacuum; at -300 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 265Retrieved 2026-10-05 |
| 230 m³/h | 230 m3/h | 50 Hz · model 50 Hz; vacuum; at -350 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 230Retrieved 2026-10-05 |
| 194 m³/h | 194 m3/h | 50 Hz · model 50 Hz; vacuum; at -400 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 194Retrieved 2026-10-05 |
| 521 m³/h | 521 m3/h | 60 Hz · model 60 Hz; compression unspecified | Source · OEM_SOURCEMax. flow: 521Retrieved 2026-10-05 |
| 502 m³/h | 502 m3/h | 60 Hz · model 60 Hz; compression; at +50 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 502Retrieved 2026-10-05 |
| 484 m³/h | 484 m3/h | 60 Hz · model 60 Hz; compression; at +100 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 484Retrieved 2026-10-05 |
| 466 m³/h | 466 m3/h | 60 Hz · model 60 Hz; compression; at +150 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 466Retrieved 2026-10-05 |
| 449 m³/h | 449 m3/h | 60 Hz · model 60 Hz; compression; at +200 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 449Retrieved 2026-10-05 |
| 432 m³/h | 432 m3/h | 60 Hz · model 60 Hz; compression; at +250 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 432Retrieved 2026-10-05 |
| 415 m³/h | 415 m3/h | 60 Hz · model 60 Hz; compression; at +300 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 415Retrieved 2026-10-05 |
| 398 m³/h | 398 m3/h | 60 Hz · model 60 Hz; compression; at +350 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 398Retrieved 2026-10-05 |
| 382 m³/h | 382 m3/h | 60 Hz · model 60 Hz; compression; at +400 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 382Retrieved 2026-10-05 |
| 366 m³/h | 366 m3/h | 60 Hz · model 60 Hz; compression; at +450 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 366Retrieved 2026-10-05 |
| 521 m³/h | 521 m3/h | 60 Hz · model 60 Hz; vacuum unspecified | Source · OEM_SOURCEMax. flow: 521Retrieved 2026-10-05 |
| 496 m³/h | 496 m3/h | 60 Hz · model 60 Hz; vacuum; at -50 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 496Retrieved 2026-10-05 |
| 474 m³/h | 474 m3/h | 60 Hz · model 60 Hz; vacuum; at -100 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 474Retrieved 2026-10-05 |
| 450 m³/h | 450 m3/h | 60 Hz · model 60 Hz; vacuum; at -150 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 450Retrieved 2026-10-05 |
| 424 m³/h | 424 m3/h | 60 Hz · model 60 Hz; vacuum; at -200 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 424Retrieved 2026-10-05 |
| 397 m³/h | 397 m3/h | 60 Hz · model 60 Hz; vacuum; at -250 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 397Retrieved 2026-10-05 |
| 368 m³/h | 368 m3/h | 60 Hz · model 60 Hz; vacuum; at -300 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 368Retrieved 2026-10-05 |
| 338 m³/h | 338 m3/h | 60 Hz · model 60 Hz; vacuum; at -350 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 338Retrieved 2026-10-05 |
| 306 m³/h | 306 m3/h | 60 Hz · model 60 Hz; vacuum; at -400 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 306Retrieved 2026-10-05 |
Ultimate pressure · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Motor power · Sourced · 8 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 5.50 kW | 5.5 kW | 50 Hz · model 50 Hz; compression; at max. flow unspecified | Source · OEM_SOURCE different frequency Installed motor size: 5.50Retrieved 2026-10-05 |
| 9.20 kW | 9.2 kW | 50 Hz · model 50 Hz; compression; at Δp max 550 mbar unspecified | Source · OEM_SOURCE different frequency Installed motor size: 9.20Retrieved 2026-10-05 |
| 5.50 kW | 5.5 kW | 50 Hz · model 50 Hz; vacuum; at max. flow unspecified | Source · OEM_SOURCE different frequency Installed motor size: 5.50Retrieved 2026-10-05 |
| 7.50 kW | 7.5 kW | 50 Hz · model 50 Hz; vacuum; at Δp max 400 mbar unspecified | Source · OEM_SOURCE different frequency Installed motor size: 7.50Retrieved 2026-10-05 |
| 5.50 kW | 5.5 kW | 60 Hz · model 60 Hz; compression; at max. flow unspecified | Source · OEM_SOURCEInstalled motor size: 5.50Retrieved 2026-10-05 |
| 9.20 kW | 9.2 kW | 60 Hz · model 60 Hz; compression; at Δp max 450 mbar unspecified | Source · OEM_SOURCEInstalled motor size: 9.20Retrieved 2026-10-05 |
| 5.50 kW | 5.5 kW | 60 Hz · model 60 Hz; vacuum; at max. flow unspecified | Source · OEM_SOURCEInstalled motor size: 5.50Retrieved 2026-10-05 |
| 9.20 kW | 9.2 kW | 60 Hz · model 60 Hz; vacuum; at Δp max 400 mbar unspecified | Source · OEM_SOURCEInstalled motor size: 9.20Retrieved 2026-10-05 |
Speed · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Noise level · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Weight · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Dimensions · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Inlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Outlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Max. pressure · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 550 mbar | 550 mbar | 50 Hz · model 50 Hz; compression unspecified | Source · OEM_SOURCE different frequency Δp max (compression): 550Retrieved 2026-10-05 |
| 450 mbar | 450 mbar | 60 Hz · model 60 Hz; compression unspecified | Source · OEM_SOURCEΔp max (compression): 450Retrieved 2026-10-05 |
Max. vacuum · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 400 mbar | 400 mbar | 50 Hz · model 50 Hz; vacuum unspecified | Source · OEM_SOURCE different frequency Δp max (vacuum): 400Retrieved 2026-10-05 |
| 400 mbar | 400 mbar | 60 Hz · model 60 Hz; vacuum unspecified | Source · OEM_SOURCEΔp max (vacuum): 400Retrieved 2026-10-05 |
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 1 | 0 |
|
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 0 | 0 | Not collected |
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 1 | 0 |
|
| Other / unclassified | 0 | 0 | Not collected |