Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for FPZ e07 TD: specifications, configurations, documents, sources, and gaps.

One model, connected records

FPZ → FPZ side channel blowers → e07 TD

Manufacturer model: e07 TD · OEM article / order number: Not collected · Equipment type: vacuum pump

Technology: Regenerative / Side Channel

Related applications: Material Handling, Pick + Place, Pneumatic Conveying, Vacuum Hold-Down
Related industries: Printing, Pulp + Paper, Woodworking + CNC

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

52 stored observations · 25 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Pumping speed · Sourced · 40 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
432 m³/h432 m3/h50 Hz · model
50 Hz; compression
unspecified
Source · OEM_SOURCE
different frequency
Max. flow: 432
Retrieved 2026-10-05
410 m³/h410 m3/h50 Hz · model
50 Hz; compression; at +50 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 410
Retrieved 2026-10-05
389 m³/h389 m3/h50 Hz · model
50 Hz; compression; at +100 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 389
Retrieved 2026-10-05
369 m³/h369 m3/h50 Hz · model
50 Hz; compression; at +150 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 369
Retrieved 2026-10-05
349 m³/h349 m3/h50 Hz · model
50 Hz; compression; at +200 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 349
Retrieved 2026-10-05
330 m³/h330 m3/h50 Hz · model
50 Hz; compression; at +250 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 330
Retrieved 2026-10-05
311 m³/h311 m3/h50 Hz · model
50 Hz; compression; at +300 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 311
Retrieved 2026-10-05
293 m³/h293 m3/h50 Hz · model
50 Hz; compression; at +350 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 293
Retrieved 2026-10-05
276 m³/h276 m3/h50 Hz · model
50 Hz; compression; at +400 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 276
Retrieved 2026-10-05
259 m³/h259 m3/h50 Hz · model
50 Hz; compression; at +450 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 259
Retrieved 2026-10-05
242 m³/h242 m3/h50 Hz · model
50 Hz; compression; at +500 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 242
Retrieved 2026-10-05
226 m³/h226 m3/h50 Hz · model
50 Hz; compression; at +550 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 226
Retrieved 2026-10-05
432 m³/h432 m3/h50 Hz · model
50 Hz; vacuum
unspecified
Source · OEM_SOURCE
different frequency
Max. flow: 432
Retrieved 2026-10-05
406 m³/h406 m3/h50 Hz · model
50 Hz; vacuum; at -50 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 406
Retrieved 2026-10-05
382 m³/h382 m3/h50 Hz · model
50 Hz; vacuum; at -100 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 382
Retrieved 2026-10-05
356 m³/h356 m3/h50 Hz · model
50 Hz; vacuum; at -150 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 356
Retrieved 2026-10-05
327 m³/h327 m3/h50 Hz · model
50 Hz; vacuum; at -200 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 327
Retrieved 2026-10-05
297 m³/h297 m3/h50 Hz · model
50 Hz; vacuum; at -250 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 297
Retrieved 2026-10-05
265 m³/h265 m3/h50 Hz · model
50 Hz; vacuum; at -300 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 265
Retrieved 2026-10-05
230 m³/h230 m3/h50 Hz · model
50 Hz; vacuum; at -350 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 230
Retrieved 2026-10-05
194 m³/h194 m3/h50 Hz · model
50 Hz; vacuum; at -400 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 194
Retrieved 2026-10-05
521 m³/h521 m3/h60 Hz · model
60 Hz; compression
unspecified
Source · OEM_SOURCE
Max. flow: 521
Retrieved 2026-10-05
502 m³/h502 m3/h60 Hz · model
60 Hz; compression; at +50 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 502
Retrieved 2026-10-05
484 m³/h484 m3/h60 Hz · model
60 Hz; compression; at +100 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 484
Retrieved 2026-10-05
466 m³/h466 m3/h60 Hz · model
60 Hz; compression; at +150 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 466
Retrieved 2026-10-05
449 m³/h449 m3/h60 Hz · model
60 Hz; compression; at +200 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 449
Retrieved 2026-10-05
432 m³/h432 m3/h60 Hz · model
60 Hz; compression; at +250 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 432
Retrieved 2026-10-05
415 m³/h415 m3/h60 Hz · model
60 Hz; compression; at +300 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 415
Retrieved 2026-10-05
398 m³/h398 m3/h60 Hz · model
60 Hz; compression; at +350 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 398
Retrieved 2026-10-05
382 m³/h382 m3/h60 Hz · model
60 Hz; compression; at +400 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 382
Retrieved 2026-10-05
366 m³/h366 m3/h60 Hz · model
60 Hz; compression; at +450 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 366
Retrieved 2026-10-05
521 m³/h521 m3/h60 Hz · model
60 Hz; vacuum
unspecified
Source · OEM_SOURCE
Max. flow: 521
Retrieved 2026-10-05
496 m³/h496 m3/h60 Hz · model
60 Hz; vacuum; at -50 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 496
Retrieved 2026-10-05
474 m³/h474 m3/h60 Hz · model
60 Hz; vacuum; at -100 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 474
Retrieved 2026-10-05
450 m³/h450 m3/h60 Hz · model
60 Hz; vacuum; at -150 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 450
Retrieved 2026-10-05
424 m³/h424 m3/h60 Hz · model
60 Hz; vacuum; at -200 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 424
Retrieved 2026-10-05
397 m³/h397 m3/h60 Hz · model
60 Hz; vacuum; at -250 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 397
Retrieved 2026-10-05
368 m³/h368 m3/h60 Hz · model
60 Hz; vacuum; at -300 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 368
Retrieved 2026-10-05
338 m³/h338 m3/h60 Hz · model
60 Hz; vacuum; at -350 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 338
Retrieved 2026-10-05
306 m³/h306 m3/h60 Hz · model
60 Hz; vacuum; at -400 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 306
Retrieved 2026-10-05
Ultimate pressure · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Motor power · Sourced · 8 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
5.50 kW5.5 kW50 Hz · model
50 Hz; compression; at max. flow
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 5.50
Retrieved 2026-10-05
9.20 kW9.2 kW50 Hz · model
50 Hz; compression; at Δp max 550 mbar
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 9.20
Retrieved 2026-10-05
5.50 kW5.5 kW50 Hz · model
50 Hz; vacuum; at max. flow
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 5.50
Retrieved 2026-10-05
7.50 kW7.5 kW50 Hz · model
50 Hz; vacuum; at Δp max 400 mbar
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 7.50
Retrieved 2026-10-05
5.50 kW5.5 kW60 Hz · model
60 Hz; compression; at max. flow
unspecified
Source · OEM_SOURCE
Installed motor size: 5.50
Retrieved 2026-10-05
9.20 kW9.2 kW60 Hz · model
60 Hz; compression; at Δp max 450 mbar
unspecified
Source · OEM_SOURCE
Installed motor size: 9.20
Retrieved 2026-10-05
5.50 kW5.5 kW60 Hz · model
60 Hz; vacuum; at max. flow
unspecified
Source · OEM_SOURCE
Installed motor size: 5.50
Retrieved 2026-10-05
9.20 kW9.2 kW60 Hz · model
60 Hz; vacuum; at Δp max 400 mbar
unspecified
Source · OEM_SOURCE
Installed motor size: 9.20
Retrieved 2026-10-05
Speed · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Noise level · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Weight · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Dimensions · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Inlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Outlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Max. pressure · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
550 mbar550 mbar50 Hz · model
50 Hz; compression
unspecified
Source · OEM_SOURCE
different frequency
Δp max (compression): 550
Retrieved 2026-10-05
450 mbar450 mbar60 Hz · model
60 Hz; compression
unspecified
Source · OEM_SOURCE
Δp max (compression): 450
Retrieved 2026-10-05
Max. vacuum · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
400 mbar400 mbar50 Hz · model
50 Hz; vacuum
unspecified
Source · OEM_SOURCE
different frequency
Δp max (vacuum): 400
Retrieved 2026-10-05
400 mbar400 mbar60 Hz · model
60 Hz; vacuum
unspecified
Source · OEM_SOURCE
Δp max (vacuum): 400
Retrieved 2026-10-05

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications10
Performance curves / test data00Not collected
Operation / service manuals00Not collected
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature10
Other / unclassified00Not collected