Gardner Denver · Sutorbilt Legend performance data

Sutorbilt Legend 4MV

BlowersOEM data
Gardner Denver Sutorbilt Legend 4MV

*Photo shows the Sutorbilt Legend series, not necessarily this exact model. Image: Gardner Denver

Blower flow
610 m³/h

Headline ratings converted to common units for comparison; the table below shows each figure exactly as published.

Technical data

Source: Gardner Denver product page · retrieved 2026-10-04
As published& outlet3,600 RPM, 7 PSIG3,600 RPM, 9 PSIG3,600 RPM, 10 PSIG2,620 RPM, 7 PSIG2,620 RPM, 9 PSIG2,620 RPM, 10 PSIG2,190 RPM, 7 PSIG2,190 RPM, 9 PSIG2,190 RPM, 10 PSIG1,760 RPM, 7 PSIG1,760 RPM, 9 PSIG1,760 RPM, 10 PSIG3,600 RPM, 6 "Hg vacuum3,600 RPM, 10 "Hg vacuum3,600 RPM, 12 "Hg vacuum3,600 RPM, 14 "Hg vacuum3,600 RPM, 15 "Hg vacuum3,600 RPM, 16 "Hg vacuum2,620 RPM, 6 "Hg vacuum2,620 RPM, 10 "Hg vacuum2,620 RPM, 12 "Hg vacuum2,620 RPM, 14 "Hg vacuum2,190 RPM, 6 "Hg vacuum2,190 RPM, 10 "Hg vacuum2,190 RPM, 12 "Hg vacuum1,760 RPM, 6 "Hg vacuum1,760 RPM, 10 "Hg vacuum1,760 RPM, 12 "Hg vacuumthe pressure "Flow" is stated at (3,600 RPM, 10 PSIG)vacuum (gauge); the pressure "Vacuum service inlet flow" is stated at (3,600 RPM, 14 "Hg vacuum)vacuum (gauge); the pressure "Vacuum service inlet flow" is stated at (3,600 RPM, 6 "Hg vacuum)vacuum (gauge); the pressure "Vacuum service inlet flow" is stated at (3,600 RPM, 12 "Hg vacuum)the pressure "Flow" is stated at (3,600 RPM, 7 PSIG)vacuum (gauge); the pressure "Vacuum service inlet flow" is stated at (3,600 RPM, 15 "Hg vacuum)vacuum (gauge); the pressure "Vacuum service inlet flow" is stated at (3,600 RPM, 16 "Hg vacuum)vacuum (gauge); the pressure "Vacuum service inlet flow" is stated at (3,600 RPM, 10 "Hg vacuum)the pressure "Flow" is stated at (3,600 RPM, 9 PSIG)
Inlet & outlet
Inlet connection
2½"-S ½"-S
oem source
Source · 2026-10-04
Flow
Blower flow
359 CFM
oem source
Source · 2026-10-04
351 CFM
oem source
Source · 2026-10-04
347 CFM
oem source
Source · 2026-10-04
245 CFM
oem source
Source · 2026-10-04
236 CFM
oem source
Source · 2026-10-04
233 CFM
oem source
Source · 2026-10-04
194 CFM
oem source
Source · 2026-10-04
186 CFM
oem source
Source · 2026-10-04
182 CFM
oem source
Source · 2026-10-04
144 CFM
oem source
Source · 2026-10-04
136 CFM
oem source
Source · 2026-10-04
132 CFM
oem source
Source · 2026-10-04
Brake horsepower
Power consumption
14.0 BHP
oem source
Source · 2026-10-04
18.0 BHP
oem source
Source · 2026-10-04
20.0 BHP
oem source
Source · 2026-10-04
10.2 BHP
oem source
Source · 2026-10-04
13.1 BHP
oem source
Source · 2026-10-04
14.5 BHP
oem source
Source · 2026-10-04
8.5 BHP
oem source
Source · 2026-10-04
10.9 BHP
oem source
Source · 2026-10-04
12.1 BHP
oem source
Source · 2026-10-04
6.8 BHP
oem source
Source · 2026-10-04
8.8 BHP
oem source
Source · 2026-10-04
9.8 BHP
oem source
Source · 2026-10-04
Vacuum service inlet flow
Inlet flow (vacuum service)
376 CFM
oem source
Source · 2026-10-04
358 CFM
oem source
Source · 2026-10-04
348 CFM
oem source
Source · 2026-10-04
337 CFM
oem source
Source · 2026-10-04
331 CFM
oem source
Source · 2026-10-04
325 CFM
oem source
Source · 2026-10-04
262 CFM
oem source
Source · 2026-10-04
243 CFM
oem source
Source · 2026-10-04
233 CFM
oem source
Source · 2026-10-04
222 CFM
oem source
Source · 2026-10-04
211 CFM
oem source
Source · 2026-10-04
193 CFM
oem source
Source · 2026-10-04
183 CFM
oem source
Source · 2026-10-04
161 CFM
oem source
Source · 2026-10-04
142 CFM
oem source
Source · 2026-10-04
132 CFM
oem source
Source · 2026-10-04
Vacuum service brake horsepower
Brake power (vacuum service)
5.9 BHP
oem source
Source · 2026-10-04
9.8 BHP
oem source
Source · 2026-10-04
11.8 BHP
oem source
Source · 2026-10-04
13.7 BHP
oem source
Source · 2026-10-04
14.7 BHP
oem source
Source · 2026-10-04
15.7 BHP
oem source
Source · 2026-10-04
4.4 BHP
oem source
Source · 2026-10-04
7.1 BHP
oem source
Source · 2026-10-04
8.6 BHP
oem source
Source · 2026-10-04
10.0 BHP
oem source
Source · 2026-10-04
3.7 BHP
oem source
Source · 2026-10-04
6.0 BHP
oem source
Source · 2026-10-04
7.2 BHP
oem source
Source · 2026-10-04
3.0 BHP
oem source
Source · 2026-10-04
4.9 BHP
oem source
Source · 2026-10-04
5.8 BHP
oem source
Source · 2026-10-04
Reference working pressure
10 psig
oem source
Source · 2026-10-20
7 psig
oem source
Source · 2026-10-20
9 psig
oem source
Source · 2026-10-20
Reference vacuum
14 inHg
oem source
Source · 2026-10-20
6 inHg
oem source
Source · 2026-10-20
12 inHg
oem source
Source · 2026-10-20
15 inHg
oem source
Source · 2026-10-20
16 inHg
oem source
Source · 2026-10-20
10 inHg
oem source
Source · 2026-10-20

Original extracted values are shown with their source and review status. Multiple values under the same condition remain separate for review.

Same family: Sutorbilt Legend 3H, Sutorbilt Legend 3HV, Sutorbilt Legend 3L, Sutorbilt Legend 3LV, Sutorbilt Legend 3M, Sutorbilt Legend 3MV, Sutorbilt Legend 4H, Sutorbilt Legend 4HV, Sutorbilt Legend 4L, Sutorbilt Legend 4LV, Sutorbilt Legend 4M, Sutorbilt Legend 5H, Sutorbilt Legend 5HV, Sutorbilt Legend 5L, Sutorbilt Legend 5LV, Sutorbilt Legend 5M, Sutorbilt Legend 5MV, Sutorbilt Legend 6H, Sutorbilt Legend 6HV, Sutorbilt Legend 6L, Sutorbilt Legend 6LV, Sutorbilt Legend 6M, Sutorbilt Legend 6MV

Reviewed operating performance · 60 Hz

Loading reviewed performance…

Documents

Documents open on the manufacturer’s site.

Service parts

No parts published for this model.

Compare with another model

Not on file yet

  • MissingGardner Denver's parts drawing (exploded view) for the Sutorbilt Legend 4MV
  • MissingA parts list for the Sutorbilt Legend 4MV

We don’t have these from Gardner Denver yet. A specialist can still help you find the right part for the Sutorbilt Legend 4MV.

Gardner Denver Sutorbilt Legend 4MV | Vac & Air