Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for Pfeiffer Vacuum+Fab Solutions DuoVane 36: specifications, configurations, documents, sources, and gaps.

One model, connected records

Pfeiffer Vacuum+Fab Solutions → DuoVane 36/70 → DuoVane 36

Manufacturer model: DuoVane 36 · OEM article / order number: Not collected · Equipment type: vacuum pump

Technology: Oil-Lubricated Rotary Vane

Related applications: Central Vacuum, Degassing, Drying, Leak Testing, Medical Suction, Packaging, Vacuum Forming
Related industries: Automotive, Food + Beverage, Medical, Metalworking, Packaging, Plastics

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

24 stored observations · 12 pass the source policy at 50 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Pumping speed · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
32 m³/h m³/h32 m3/h50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
Nominal pumping speed: 32 m³/h
Retrieved 2026-10-02
36 m³/h m³/h36 m3/h60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Nominal pumping speed: 36 m³/h
Retrieved 2026-10-02
Ultimate pressure · Sourced · 4 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
2 · 10⁻³ hPa(mbar) hPa(mbar)0.002 mbar50 Hz · model
ISO 50 Hz; (gas-ballast valve closed)
unspecified
Source · OEM_VERIFIED
Ultimate pressure (gas-ballast valve closed): 2 · 10⁻³ hPa(mbar)
Retrieved 2026-10-02
3 · 10⁻³ hPa(mbar) hPa(mbar)0.003 mbar50 Hz · model
ISO 50 Hz; (gas-ballast valve open)
unspecified
Source · OEM_VERIFIED
Ultimate pressure (gas-ballast valve open): 3 · 10⁻³ hPa(mbar)
Retrieved 2026-10-02
2 · 10⁻³ hPa(mbar) hPa(mbar)0.002 mbar60 Hz · model
ISO 60 Hz; (gas-ballast valve closed)
unspecified
Source · OEM_VERIFIED
different frequency
Ultimate pressure (gas-ballast valve closed): 2 · 10⁻³ hPa(mbar)
Retrieved 2026-10-02
3 · 10⁻³ hPa(mbar) hPa(mbar)0.003 mbar60 Hz · model
ISO 60 Hz; (gas-ballast valve open)
unspecified
Source · OEM_VERIFIED
different frequency
Ultimate pressure (gas-ballast valve open): 3 · 10⁻³ hPa(mbar)
Retrieved 2026-10-02
Motor power · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
1.1 kW kW1.1 kW50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
Nominal motor rating: 1.1 kW
Retrieved 2026-10-02
1.3 kW kW1.3 kW60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Nominal motor rating: 1.3 kW
Retrieved 2026-10-02
Speed · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
1500 min⁻¹ min⁻¹1500 rpm50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
Nominal motor speed: 1500 min⁻¹
Retrieved 2026-10-02
1800 min⁻¹ min⁻¹1800 rpm60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Nominal motor speed: 1800 min⁻¹
Retrieved 2026-10-02
Noise level · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
61 dB(A) dB(A)61 dB(A)50 Hz · model
ISO 50 Hz; (50 Hz)
unspecified
Source · OEM_SOURCE
Sound pressure level (50 Hz): 61 dB(A)
Retrieved 2026-10-02
61 dB(A) dB(A)61 dB(A)Frequency not stated · model
ISO 60 Hz; (50 Hz)
unspecified
Source · OEM_SOURCE
Sound pressure level (50 Hz): 61 dB(A)
Retrieved 2026-10-02
Weight · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
68 kg kg68 kg50 Hz · model
ISO 50 Hz; approx.
unspecified
Source · OEM_VERIFIED
Weight approx.: 68 kg
Retrieved 2026-10-02
68 kg kg68 kg60 Hz · model
ISO 60 Hz; approx.
unspecified
Source · OEM_VERIFIED
different frequency
Weight approx.: 68 kg
Retrieved 2026-10-02
Dimensions · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
645 x 240 x 340 mm mm— 50 Hz · model
ISO 50 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
Dimensions (L x W x H): 645 x 240 x 340 mm
Retrieved 2026-10-02
645 x 240 x 340 mm mm— 60 Hz · model
ISO 60 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
different frequency
Dimensions (L x W x H): 645 x 240 x 340 mm
Retrieved 2026-10-02
Inlet connection · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
DN 40 ISO-KF — 50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
Gas inlet: DN 40 ISO-KF
Retrieved 2026-10-02
DN 40 ISO-KF — 60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_SOURCE
different frequency
Gas inlet: DN 40 ISO-KF
Retrieved 2026-10-02
Outlet connection · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
DN 40 ISO-KF — 50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
Gas outlet: DN 40 ISO-KF
Retrieved 2026-10-02
DN 40 ISO-KF — 60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_SOURCE
different frequency
Gas outlet: DN 40 ISO-KF
Retrieved 2026-10-02
Motor Phase · Needs review · 2 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
Three-phase — 50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
Motor phase: Three-phase
Retrieved 2026-10-02
Three-phase — 60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_SOURCE
different frequency
Motor phase: Three-phase
Retrieved 2026-10-02
Oil capacity · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
3.2 l l3.2 l50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_VERIFIED
Oil capacity: 3.2 l
Retrieved 2026-10-02
3.2 l l3.2 l60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Oil capacity: 3.2 l
Retrieved 2026-10-02

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications10
Performance curves / test data00Not collected
Operation / service manuals10
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature00Not collected
Other / unclassified00Not collected