Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Powerex · Powerex Laboratory Scroll Enclosure Systems

LSED3006

ScrollOil-freeOEM data
Powerex LSED3006

*Photo shows another model from the Powerex Scroll range, not this exact model. Image: Powerex

Free air delivery
207 m³/h
Motor power
22.4 kW

Headline ratings converted to common units for comparison; the table below shows each figure exactly as published.

Technical data

Source: Powerex product page · retrieved 2026-10-06
As publishedSimplex Systems; (SCFM @ 145 PSIG / *100 PSIG)OSHPD Certified Duplex Systems; (SCFM @ 145 PSIG / *100 PSIG)the pressure "Capacity (SCFM @ 145 PSIG / *100 PSIG)" is stated at (Simplex Systems; (SCFM @ 145 PSIG / *100 PSIG))as printed: "HP"
Capacity (SCFM @ 145 PSIG / *100 PSIG)
Free air delivery
121.6 SCFM
oem source
Source · 2026-10-06
121.6 SCFM
oem source
Source · 2026-10-06
Reference working pressure
145 psig
oem source
Source · 2026-10-20
Motor power
30 HP
oem source
Source · 2026-10-20

Original extracted values are shown with their source and review status. Multiple values under the same condition remain separate for review.

Same family: LSE1003, LSE1504, LSE2005, LSE3005, LSE4005, LSED4006

Reviewed operating performance · 60 Hz

Loading reviewed performance…

Documents

Documents open on the manufacturer’s site.

Parts diagrams

Exploded views from Powerex’s own documents, with each position and part number as printed. Select a part to see what it fits, who sells it and what replaces it.

Exploded view · 593102 1119, page 99 positions

The positions on this drawing haven’t been placed yet: choose a position in the list for its part. Drag to move, pinch or Ctrl + scroll to zoom.

Select a part on the drawing or in the list to see its number, what it fits and where to get it. Turn on “select several” to build one quote for many parts.

Pos.Part numberDescriptionQty
CW207591AV(Duplex Only) Lag Pressure Switch (90-110)
PS005849AVControl Transformer As needed
JP007708AVPrimary Fuses (2 Per Transformer) 3A As needed
JP007712AVTransformer Fusing 200VA 208-460V (2.5A)
PE000411AVReserve Transformer Relay (Duplex Systems) As needed
PE000418AJPLC with Program Consult factory
SL300702AVNo loss drain assembly Consult factory
PE000403AVRelay
PE000552AVHOA switch (Illuminated)

Positions and part numbers as printed in Powerex’s 593102 1119, page 9 · view the source document