Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Gardner Denver · HeliFlow performance data

HeliFlow HF 408

BlowersOEM data
Gardner Denver HeliFlow HF 408

*Photo shows the HeliFlow series, not necessarily this exact model. Image: Gardner Denver

Blower flow
1,010 m³/h

Headline ratings converted to common units for comparison; the table below shows each figure exactly as published.

Technical data

Source: Gardner Denver product page · retrieved 2026-10-04
As published4000 RPM, 5 PSI4000 RPM, 7 PSI4000 RPM, 10 PSI4000 RPM, 12 PSI4000 RPM, 15 PSI3600 RPM, 5 PSI3600 RPM, 7 PSI3600 RPM, 10 PSI3600 RPM, 12 PSI3600 RPM, 15 PSI2620 RPM, 5 PSI2620 RPM, 7 PSI2620 RPM, 10 PSI2620 RPM, 12 PSI2620 RPM, 15 PSI2190 RPM, 5 PSI2190 RPM, 7 PSI2190 RPM, 10 PSI2190 RPM, 12 PSI2190 RPM, 15 PSI1760 RPM, 5 PSI1760 RPM, 7 PSI1760 RPM, 10 PSI1760 RPM, 12 PSI1760 RPM, 15 PSI4000 RPM, 10 inHG vacuum4000 RPM, 12 inHG vacuum4000 RPM, 14 inHG vacuum4000 RPM, 16 inHG vacuum3600 RPM, 10 inHG vacuum3600 RPM, 12 inHG vacuum3600 RPM, 14 inHG vacuum3600 RPM, 16 inHG vacuum2620 RPM, 10 inHG vacuum2620 RPM, 12 inHG vacuum2620 RPM, 14 inHG vacuum2620 RPM, 16 inHG vacuum2190 RPM, 10 inHG vacuum2190 RPM, 12 inHG vacuum2190 RPM, 14 inHG vacuum2190 RPM, 16 inHG vacuum1760 RPM, 10 inHG vacuum1760 RPM, 12 inHG vacuum1760 RPM, 14 inHG vacuumvacuum (gauge); the pressure "Vacuum service inlet flow" is stated at (4000 RPM, 10 inHG vacuum)the pressure "Flow" is stated at (4000 RPM, 12 PSI)vacuum (gauge); the pressure "Vacuum service inlet flow" is stated at (4000 RPM, 12 inHG vacuum)the pressure "Flow" is stated at (4000 RPM, 5 PSI)the pressure "Flow" is stated at (4000 RPM, 7 PSI)vacuum (gauge); the pressure "Vacuum service inlet flow" is stated at (4000 RPM, 16 inHG vacuum)the pressure "Flow" is stated at (4000 RPM, 15 PSI)vacuum (gauge); the pressure "Vacuum service inlet flow" is stated at (4000 RPM, 14 inHG vacuum)the pressure "Flow" is stated at (4000 RPM, 10 PSI)
Flow
Blower flow
592 CFM
oem source
Source · 2026-10-04
577 CFM
oem source
Source · 2026-10-04
555 CFM
oem source
Source · 2026-10-04
541 CFM
oem source
Source · 2026-10-04
516 CFM
oem source
Source · 2026-10-04
529 CFM
oem source
Source · 2026-10-04
515 CFM
oem source
Source · 2026-10-04
493 CFM
oem source
Source · 2026-10-04
479 CFM
oem source
Source · 2026-10-04
458 CFM
oem source
Source · 2026-10-04
369 CFM
oem source
Source · 2026-10-04
356 CFM
oem source
Source · 2026-10-04
336 CFM
oem source
Source · 2026-10-04
324 CFM
oem source
Source · 2026-10-04
307 CFM
oem source
Source · 2026-10-04
297 CFM
oem source
Source · 2026-10-04
284 CFM
oem source
Source · 2026-10-04
265 CFM
oem source
Source · 2026-10-04
253 CFM
oem source
Source · 2026-10-04
240 CFM
oem source
Source · 2026-10-04
223 CFM
oem source
Source · 2026-10-04
211 CFM
oem source
Source · 2026-10-04
193 CFM
oem source
Source · 2026-10-04
182 CFM
oem source
Source · 2026-10-04
170 CFM
oem source
Source · 2026-10-04
Brake horsepower
Power consumption
19.2 BHP
oem source
Source · 2026-10-04
25.3 BHP
oem source
Source · 2026-10-04
34.2 BHP
oem source
Source · 2026-10-04
40.0 BHP
oem source
Source · 2026-10-04
50.5 BHP
oem source
Source · 2026-10-04
16.8 BHP
oem source
Source · 2026-10-04
22.3 BHP
oem source
Source · 2026-10-04
30.3 BHP
oem source
Source · 2026-10-04
35.5 BHP
oem source
Source · 2026-10-04
45.1 BHP
oem source
Source · 2026-10-04
11.5 BHP
oem source
Source · 2026-10-04
15.4 BHP
oem source
Source · 2026-10-04
21.1 BHP
oem source
Source · 2026-10-04
24.8 BHP
oem source
Source · 2026-10-04
31.4 BHP
oem source
Source · 2026-10-04
9.2 BHP
oem source
Source · 2026-10-04
12.5 BHP
oem source
Source · 2026-10-04
17.2 BHP
oem source
Source · 2026-10-04
20.2 BHP
oem source
Source · 2026-10-04
25.6 BHP
oem source
Source · 2026-10-04
7.1 BHP
oem source
Source · 2026-10-04
9.7 BHP
oem source
Source · 2026-10-04
13.4 BHP
oem source
Source · 2026-10-04
15.7 BHP
oem source
Source · 2026-10-04
20.1 BHP
oem source
Source · 2026-10-04
Vacuum service inlet flow
Inlet flow (vacuum service)
584 CFM
oem source
Source · 2026-10-04
573 CFM
oem source
Source · 2026-10-04
560 CFM
oem source
Source · 2026-10-04
545 CFM
oem source
Source · 2026-10-04
523 CFM
oem source
Source · 2026-10-04
511 CFM
oem source
Source · 2026-10-04
497 CFM
oem source
Source · 2026-10-04
482 CFM
oem source
Source · 2026-10-04
364 CFM
oem source
Source · 2026-10-04
351 CFM
oem source
Source · 2026-10-04
337 CFM
oem source
Source · 2026-10-04
321 CFM
oem source
Source · 2026-10-04
292 CFM
oem source
Source · 2026-10-04
278 CFM
oem source
Source · 2026-10-04
264 CFM
oem source
Source · 2026-10-04
247 CFM
oem source
Source · 2026-10-04
217 CFM
oem source
Source · 2026-10-04
204 CFM
oem source
Source · 2026-10-04
189 CFM
oem source
Source · 2026-10-04
Vacuum service brake horsepower
Brake power (vacuum service)
17.7 BHP
oem source
Source · 2026-10-04
20.1 BHP
oem source
Source · 2026-10-04
22.6 BHP
oem source
Source · 2026-10-04
25.1 BHP
oem source
Source · 2026-10-04
15.3 BHP
oem source
Source · 2026-10-04
17.5 BHP
oem source
Source · 2026-10-04
19.8 BHP
oem source
Source · 2026-10-04
22.1 BHP
oem source
Source · 2026-10-04
10.1 BHP
oem source
Source · 2026-10-04
11.8 BHP
oem source
Source · 2026-10-04
13.6 BHP
oem source
Source · 2026-10-04
15.4 BHP
oem source
Source · 2026-10-04
8.1 BHP
oem source
Source · 2026-10-04
9.6 BHP
oem source
Source · 2026-10-04
11.1 BHP
oem source
Source · 2026-10-04
12.8 BHP
oem source
Source · 2026-10-04
6.3 BHP
oem source
Source · 2026-10-04
7.6 BHP
oem source
Source · 2026-10-04
8.9 BHP
oem source
Source · 2026-10-04
Reference vacuum
10 inHg
oem source
Source · 2026-10-20
12 inHg
oem source
Source · 2026-10-20
16 inHg
oem source
Source · 2026-10-20
14 inHg
oem source
Source · 2026-10-20
Reference working pressure
12 psi
oem source
Source · 2026-10-20
5 psi
oem source
Source · 2026-10-20
7 psi
oem source
Source · 2026-10-20
15 psi
oem source
Source · 2026-10-20
10 psi
oem source
Source · 2026-10-20

Original extracted values are shown with their source and review status. Multiple values under the same condition remain separate for review.

Same family: HeliFlow HF 406, HeliFlow HF 412, HeliFlow HF 514, HeliFlow HF 616, HeliFlow HF 624, HeliFlow HF 817, HeliFlow HF 825

Reviewed operating performance · 60 Hz

Loading reviewed performance…

Documents

Documents open on the manufacturer’s site.

Service parts

No parts published for this model.

Compare with another model

Not on file yet

  • MissingGardner Denver's parts drawing (exploded view) for the HeliFlow HF 408
  • MissingA parts list for the HeliFlow HF 408

We don’t have these from Gardner Denver yet. A specialist can still help you find the right part for the HeliFlow HF 408.