*Photo shows the Sutorbilt 8000 series, not necessarily this exact model. Image: Gardner Denver

Max. pressure
11.3 psig
Blower flow
16,000 m³/h

Headline ratings converted to common units for comparison; the table below shows each figure exactly as published.

Technical data

Source: Gardner Denver product page · retrieved 2026-10-04
As publishedValue1250 RPM, 6 PSIG1250 RPM, 8 PSIG1250 RPM, 10 PSIG965 RPM, 6 PSIG965 RPM, 8 PSIG965 RPM, 10 PSIG1250 RPM, 8" Hg vacuum1250 RPM, 10" Hg vacuum1250 RPM, 12" Hg vacuum1250 RPM, 14" Hg vacuum1250 RPM, 16" Hg vacuum965 RPM, 8" Hg vacuum965 RPM, 10" Hg vacuum965 RPM, 12" Hg vacuum965 RPM, 14" Hg vacuum965 RPM, 16" Hg vacuum
Full rated pressure
Max. pressure
11.3 PSIG
oem source
Source · 2026-10-04
Flow
Blower flow
9407 CFM
oem source
Source · 2026-10-04
9277 CFM
oem source
Source · 2026-10-04
9162 CFM
oem source
Source · 2026-10-04
7070 CFM
oem source
Source · 2026-10-04
6940 CFM
oem source
Source · 2026-10-04
6825 CFM
oem source
Source · 2026-10-04
Brake horsepower
Power consumption
302 BHP
oem source
Source · 2026-10-04
391 BHP
oem source
Source · 2026-10-04
481 BHP
oem source
Source · 2026-10-04
223 BHP
oem source
Source · 2026-10-04
292 BHP
oem source
Source · 2026-10-04
361 BHP
oem source
Source · 2026-10-04
Vacuum service inlet flow
Inlet flow (vacuum service)
9452 CFM
oem source
Source · 2026-10-04
9315 CFM
oem source
Source · 2026-10-04
9170 CFM
oem source
Source · 2026-10-04
9011 CFM
oem source
Source · 2026-10-04
8630 CFM
oem source
Source · 2026-10-04
7115 CFM
oem source
Source · 2026-10-04
6977 CFM
oem source
Source · 2026-10-04
6832 CFM
oem source
Source · 2026-10-04
6674 CFM
oem source
Source · 2026-10-04
6293 CFM
oem source
Source · 2026-10-04
Vacuum service brake horsepower
Brake power (vacuum service)
201 BHP
oem source
Source · 2026-10-04
242 BHP
oem source
Source · 2026-10-04
284 BHP
oem source
Source · 2026-10-04
325 BHP
oem source
Source · 2026-10-04
367 BHP
oem source
Source · 2026-10-04
147 BHP
oem source
Source · 2026-10-04
180 BHP
oem source
Source · 2026-10-04
213 BHP
oem source
Source · 2026-10-04
246 BHP
oem source
Source · 2026-10-04
279 BHP
oem source
Source · 2026-10-04

Original extracted values are shown with their source and review status. Multiple values under the same condition remain separate for review.

Same family: Sutorbilt 1008, Sutorbilt 1011, Sutorbilt 1013, Sutorbilt 1016, Sutorbilt 1018, Sutorbilt 1021, Sutorbilt 1024, Sutorbilt 1030, Sutorbilt 1213, Sutorbilt 1216, Sutorbilt 1218, Sutorbilt 1220, Sutorbilt 1223, Sutorbilt 1226, Sutorbilt 1230, Sutorbilt 1236, Sutorbilt 1415, Sutorbilt 1419, Sutorbilt 1421, Sutorbilt 1423, Sutorbilt 1426, Sutorbilt 1437, Sutorbilt 1442, Sutorbilt 1617, Sutorbilt 1623, Sutorbilt 1626, Sutorbilt 1630, Sutorbilt 1636, Sutorbilt 1640, Sutorbilt 1643, Sutorbilt 1648

Reviewed operating performance · 60 Hz

Loading reviewed performance…

Documents

Documents open on the manufacturer’s site.

Service parts

No parts published for this model.

Compare with another model

Not on file yet

  • MissingGardner Denver's parts drawing (exploded view) for the Sutorbilt 1431
  • MissingA parts list for the Sutorbilt 1431

We don’t have these from Gardner Denver yet. A specialist can still help you find the right part for the Sutorbilt 1431.

Gardner Denver Sutorbilt 1431 | Vac & Air