Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Gardner Denver · Sutorbilt 8000 performance data

Sutorbilt 1640

BlowersOEM data
Gardner Denver Sutorbilt 1640

*Photo shows the Sutorbilt 8000 series, not necessarily this exact model. Image: Gardner Denver

Max. pressure
10 psig
Blower flow
23,700 m³/h

Headline ratings converted to common units for comparison; the table below shows each figure exactly as published.

Technical data

Source: Gardner Denver product page · retrieved 2026-10-04
As publishedValue1100 RPM, 6 PSIG1100 RPM, 8 PSIG1100 RPM, 10 PSIG880 RPM, 6 PSIG880 RPM, 8 PSIG880 RPM, 10 PSIG1100 RPM, 8" Hg vacuum1100 RPM, 10" Hg vacuum1100 RPM, 12" Hg vacuum1100 RPM, 14" Hg vacuum880 RPM, 8" Hg vacuum880 RPM, 10" Hg vacuum880 RPM, 12" Hg vacuum880 RPM, 14" Hg vacuum
Full rated pressure
Max. pressure
10.0 PSIG
oem source
Source · 2026-10-04
Flow
Blower flow
13925 CFM
oem source
Source · 2026-10-04
13709 CFM
oem source
Source · 2026-10-04
13518 CFM
oem source
Source · 2026-10-04
10860 CFM
oem source
Source · 2026-10-04
10644 CFM
oem source
Source · 2026-10-04
10453 CFM
oem source
Source · 2026-10-04
Brake horsepower
Power consumption
460 BHP
oem source
Source · 2026-10-04
594 BHP
oem source
Source · 2026-10-04
728 BHP
oem source
Source · 2026-10-04
351 BHP
oem source
Source · 2026-10-04
458 BHP
oem source
Source · 2026-10-04
565 BHP
oem source
Source · 2026-10-04
Vacuum service inlet flow
Inlet flow (vacuum service)
14000 CFM
oem source
Source · 2026-10-04
13771 CFM
oem source
Source · 2026-10-04
13530 CFM
oem source
Source · 2026-10-04
13268 CFM
oem source
Source · 2026-10-04
10936 CFM
oem source
Source · 2026-10-04
10707 CFM
oem source
Source · 2026-10-04
10466 CFM
oem source
Source · 2026-10-04
10203 CFM
oem source
Source · 2026-10-04
Vacuum service brake horsepower
Brake power (vacuum service)
306 BHP
oem source
Source · 2026-10-04
368 BHP
oem source
Source · 2026-10-04
430 BHP
oem source
Source · 2026-10-04
491 BHP
oem source
Source · 2026-10-04
232 BHP
oem source
Source · 2026-10-04
283 BHP
oem source
Source · 2026-10-04
333 BHP
oem source
Source · 2026-10-04
384 BHP
oem source
Source · 2026-10-04

Original extracted values are shown with their source and review status. Multiple values under the same condition remain separate for review.

Same family: Sutorbilt 1008, Sutorbilt 1011, Sutorbilt 1013, Sutorbilt 1016, Sutorbilt 1018, Sutorbilt 1021, Sutorbilt 1024, Sutorbilt 1030, Sutorbilt 1213, Sutorbilt 1216, Sutorbilt 1218, Sutorbilt 1220, Sutorbilt 1223, Sutorbilt 1226, Sutorbilt 1230, Sutorbilt 1236, Sutorbilt 1415, Sutorbilt 1419, Sutorbilt 1421, Sutorbilt 1423, Sutorbilt 1426, Sutorbilt 1431, Sutorbilt 1437, Sutorbilt 1442, Sutorbilt 1617, Sutorbilt 1623, Sutorbilt 1626, Sutorbilt 1630, Sutorbilt 1636, Sutorbilt 1643, Sutorbilt 1648

Reviewed operating performance · 60 Hz

Loading reviewed performance…

Documents

Documents open on the manufacturer’s site.

Service parts

No parts published for this model.

Compare with another model

Not on file yet

  • MissingGardner Denver's parts drawing (exploded view) for the Sutorbilt 1640
  • MissingA parts list for the Sutorbilt 1640

We don’t have these from Gardner Denver yet. A specialist can still help you find the right part for the Sutorbilt 1640.

Gardner Denver Sutorbilt 1640 | Vac & Air