Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Gardner Denver · Sutorbilt 4500 performance data

Sutorbilt 820

BlowersOEM data
Gardner Denver Sutorbilt 820

*Photo shows the Sutorbilt 4500 series, not necessarily this exact model. Image: Gardner Denver

Blower flow
5,540 m³/h

Headline ratings converted to common units for comparison; the table below shows each figure exactly as published.

Technical data

Source: Gardner Denver product page · retrieved 2026-10-04
As published2100 RPM, 6 PSI2100 RPM, 8 PSI1910 RPM, 6 PSI1910 RPM, 8 PSI1770 RPM, 6 PSI1770 RPM, 8 PSI1460 RPM, 6 PSI1460 RPM, 8 PSI1170 RPM, 6 PSI1170 RPM, 8 PSI2100 RPM, 8 "Hg vacuum2100 RPM, 10 "Hg vacuum2100 RPM, 12 "Hg vacuum2100 RPM, 15 "Hg vacuum2100 RPM, 16 "Hg vacuum1910 RPM, 8 "Hg vacuum1910 RPM, 10 "Hg vacuum1910 RPM, 12 "Hg vacuum1910 RPM, 15 "Hg vacuum1910 RPM, 16 "Hg vacuum1770 RPM, 8 "Hg vacuum1770 RPM, 10 "Hg vacuum1770 RPM, 12 "Hg vacuum1770 RPM, 15 "Hg vacuum1770 RPM, 16 "Hg vacuum1460 RPM, 8 "Hg vacuum1460 RPM, 10 "Hg vacuum1460 RPM, 12 "Hg vacuum1460 RPM, 15 "Hg vacuum1170 RPM, 8 "Hg vacuum1170 RPM, 10 "Hg vacuum1170 RPM, 12 "Hg vacuum1170 RPM, 15 "Hg vacuumvacuum (gauge); the pressure "Vacuum service inlet flow" is stated at (2100 RPM, 8 "Hg vacuum)vacuum (gauge); the pressure "Vacuum service inlet flow" is stated at (2100 RPM, 16 "Hg vacuum)vacuum (gauge); the pressure "Vacuum service inlet flow" is stated at (2100 RPM, 10 "Hg vacuum)the pressure "Flow" is stated at (2100 RPM, 6 PSI)vacuum (gauge); the pressure "Vacuum service inlet flow" is stated at (2100 RPM, 12 "Hg vacuum)the pressure "Flow" is stated at (2100 RPM, 8 PSI)vacuum (gauge); the pressure "Vacuum service inlet flow" is stated at (2100 RPM, 15 "Hg vacuum)
Flow
Blower flow
3258 CFM
oem source
Source · 2026-10-04
3197 CFM
oem source
Source · 2026-10-04
2927 CFM
oem source
Source · 2026-10-04
2866 CFM
oem source
Source · 2026-10-04
2683 CFM
oem source
Source · 2026-10-04
2622 CFM
oem source
Source · 2026-10-04
2144 CFM
oem source
Source · 2026-10-04
2083 CFM
oem source
Source · 2026-10-04
1640 CFM
oem source
Source · 2026-10-04
1578 CFM
oem source
Source · 2026-10-04
Brake horsepower
Power consumption
106.6 BHP
oem source
Source · 2026-10-04
138.5 BHP
oem source
Source · 2026-10-04
95.2 BHP
oem source
Source · 2026-10-04
124.2 BHP
oem source
Source · 2026-10-04
87.2 BHP
oem source
Source · 2026-10-04
114.0 BHP
oem source
Source · 2026-10-04
70.2 BHP
oem source
Source · 2026-10-04
92.3 BHP
oem source
Source · 2026-10-04
55.2 BHP
oem source
Source · 2026-10-04
72.9 BHP
oem source
Source · 2026-10-04
Vacuum service inlet flow
Inlet flow (vacuum service)
3279 CFM
oem source
Source · 2026-10-04
3214 CFM
oem source
Source · 2026-10-04
3146 CFM
oem source
Source · 2026-10-04
3032 CFM
oem source
Source · 2026-10-04
2989 CFM
oem source
Source · 2026-10-04
2949 CFM
oem source
Source · 2026-10-04
2884 CFM
oem source
Source · 2026-10-04
2816 CFM
oem source
Source · 2026-10-04
2701 CFM
oem source
Source · 2026-10-04
2658 CFM
oem source
Source · 2026-10-04
2705 CFM
oem source
Source · 2026-10-04
2640 CFM
oem source
Source · 2026-10-04
2572 CFM
oem source
Source · 2026-10-04
2458 CFM
oem source
Source · 2026-10-04
2415 CFM
oem source
Source · 2026-10-04
2166 CFM
oem source
Source · 2026-10-04
2101 CFM
oem source
Source · 2026-10-04
2032 CFM
oem source
Source · 2026-10-04
1918 CFM
oem source
Source · 2026-10-04
1661 CFM
oem source
Source · 2026-10-04
1596 CFM
oem source
Source · 2026-10-04
1528 CFM
oem source
Source · 2026-10-04
1414 CFM
oem source
Source · 2026-10-04
Vacuum service brake horsepower
Brake power (vacuum service)
70.7 BHP
oem source
Source · 2026-10-04
85.6 BHP
oem source
Source · 2026-10-04
100.5 BHP
oem source
Source · 2026-10-04
122.9 BHP
oem source
Source · 2026-10-04
130.3 BHP
oem source
Source · 2026-10-04
63.0 BHP
oem source
Source · 2026-10-04
76.7 BHP
oem source
Source · 2026-10-04
90.4 BHP
oem source
Source · 2026-10-04
110.9 BHP
oem source
Source · 2026-10-04
117.7 BHP
oem source
Source · 2026-10-04
57.6 BHP
oem source
Source · 2026-10-04
70.3 BHP
oem source
Source · 2026-10-04
83.1 BHP
oem source
Source · 2026-10-04
102.2 BHP
oem source
Source · 2026-10-04
108.6 BHP
oem source
Source · 2026-10-04
46.2 BHP
oem source
Source · 2026-10-04
56.9 BHP
oem source
Source · 2026-10-04
67.5 BHP
oem source
Source · 2026-10-04
83.5 BHP
oem source
Source · 2026-10-04
36.3 BHP
oem source
Source · 2026-10-04
44.9 BHP
oem source
Source · 2026-10-04
53.5 BHP
oem source
Source · 2026-10-04
66.3 BHP
oem source
Source · 2026-10-04
Reference vacuum
8 inHg
oem source
Source · 2026-10-20
16 inHg
oem source
Source · 2026-10-20
10 inHg
oem source
Source · 2026-10-20
12 inHg
oem source
Source · 2026-10-20
15 inHg
oem source
Source · 2026-10-20
Reference working pressure
6 psi
oem source
Source · 2026-10-20
8 psi
oem source
Source · 2026-10-20

Original extracted values are shown with their source and review status. Multiple values under the same condition remain separate for review.

Same family: Sutorbilt 608, Sutorbilt 612, Sutorbilt 615, Sutorbilt 618, Sutorbilt 711, Sutorbilt 713, Sutorbilt 716, Sutorbilt 721, Sutorbilt 812, Sutorbilt 816, Sutorbilt 824

Reviewed operating performance · 60 Hz

Loading reviewed performance…

Documents

Documents open on the manufacturer’s site.

Service parts

No parts published for this model.

Compare with another model

Not on file yet

  • MissingGardner Denver's parts drawing (exploded view) for the Sutorbilt 820
  • MissingA parts list for the Sutorbilt 820

We don’t have these from Gardner Denver yet. A specialist can still help you find the right part for the Sutorbilt 820.